Boiler houses
Showing all 8 results
66 105 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,21
- Thermal power, MW 0,25
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 0,278
- Diesel fuel consumption, kg/h 23
- Diesel fuel consumption, l/hour 28
- Methane consumption, nm3/hour 30
90 261 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,21
- Thermal power, MW 0,25
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 0,278
- Diesel fuel consumption, kg/hour 23
- Diesel fuel consumption, l/h 28
- Methane consumption, nm3/hour 30
74 523 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0Boiler water volume, m
- Thermal power, MW 0,5
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 0,556
- Diesel fuel consumption, kg/hour 46
- Diesel fuel consumption, l/h 56
- Methane consumption, nm3/hour 59
104 127 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0Boiler water volume, m
- Thermal power, MW 0,5
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 0,556
- Diesel fuel consumption, kg/hour 46
- Diesel fuel consumption, l/h 56
- Methane consumption, nm3/hour 59
87 108 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,6
- Thermal power, MW 0,7
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 0,778
- Diesel fuel consumption, kg/hour 65
- Diesel fuel consumption, l/h 78
- Methane consumption, nm3/hour 83
115 027 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,6
- Thermal power, MW 0,7
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 0,778
- Diesel fuel consumption, kg/hour 65
- Diesel fuel consumption, l/h 78
- Methane consumption, nm3/hour 83
121 779 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,86
- Thermal power, MW 23 866 $
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 1,11
- Diesel fuel consumption, kg/hour 93
- Diesel fuel consumption, l/h 112
- Methane consumption, nm3/hour 118
166 638 THE VILLAGE
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,86
- Thermal power, MW 23 866 $
- Water temperature not higher, °C 95
- Thermal power of the burner, not less, MW 1,11
- Diesel fuel consumption, kg/hour 93
- Diesel fuel consumption, l/h 112
- Methane consumption, nm3/hour 118